Impact Analysis of Temperature and Humidity Conditions on Electrochemical Sensor Response in Ambient Air Quality Monitoring | Sapiens
← Research & Citations
Research 2018

Impact Analysis of Temperature and Humidity Conditions on Electrochemical Sensor Response in Ambient Air Quality Monitoring

P. Wei, Z. Ning, et al. · Sensors · DOI: 10.3390/s18020059

Systematic analysis quantified how temperature and humidity affect electrochemical CO/NO/NO2 sensor response, informing correction methods for reliable ambient air-quality monitoring.